BOSCH PRS-FINS Fiber interface, single mode

Vendor: BOSCH
Description BOSCH PRS-FINS Fiber interface, single mode Most of the Praesideo system units have come along with plastic fiber optic interfaces. Plastic fiber is used for interconnecting the nodes which are less than 50 meters...
$1,516.00
Title

BOSCH PRS-FINS Fiber interface, single mode

Most of the Praesideo system units have come along with plastic fiber optic interfaces. Plastic fiber is used for interconnecting the nodes which are less than 50 meters apart. For distances of more than 50 meters, glass fiber optic cable is used. A fiber interface is converting from plastic to glass fiber and vice versa. The fiber interfaces have a power supply input for providing the power to remote network sections and two control inputs. The control inputs are capable of passinig on supervision information about the power supply connected to the fiber interface.

Functions
These units interface glass fiber optical cable that comes along with plastic fiber optical cable and supporting redundant wiring topology. In many applications this is necessary, because glass fiber are capable to bridge much longer distances than plastic fiber. Any conversion to glass fiber must be converted back to plastic fiber before other Praesideo units are possible to be attached, since they all have plastic fiber interfaces. This means that these units are always used in pairs.

Each interface are capable to use an external 48 VDC power supply for providing power for itself, as well as for remote parts of the network. If there is no external power source, the interface comes using the power from the network controller. The PRS-FIN and PRS-FINS have two control inputs. These are possible to be used for accepting e.g. the fault output of the external power supply (UPS), allowing the units to monitor the power supply and report faults to the network controller. The fiber interfaces have two LEDs for diagnostic purposes.

The PRS-FINS is the same as the PRS-FIN, except that it accepts single-mode glass optical fiber instead of multi-mode glass optical fiber. However, this does not increase the maximum permitted cable length of a Praesideo network.

Controls and indicators

Power status LED
• Network status LED

Interconnections
• Network connection for plastic optical fiber
• Network connection for glass optical fiber
• External power supply input
• Two control inputs

Features

  • Redundant network connection
  • Indicators for power and fault status
  • Two supervised control inputs
  • Can use a local power supply

Electrical

Power consumption
4.6W (DC)

External power supply

Voltage
24 to 56 VDC, 48 VDC nominal
Current
2.5A maximum (5 A peak <2 s)

Control Inputs

Control Inputs
2
Connector
Screw terminals
Operation
Closing contact (with supervision)

Glass Optical Fiber Interface

Connector
SC (Avago AFCT-5805BZ transceiver)
Wavelength
1300 nm
Cable type
9/125 Mum single-mode

Environmental

Operating temperature
-5 to 55 deg. C (23 to 131 deg. F)
Storage temperature
-20 to 70 deg. C (-4 to 158 deg. F)
Humidity
15% to 90%
Air pressure
600 to 1100 hPa

Certifications and Approvals

Certifications and Approvals
Safety: Acc. to IEC 60065 / EN 60065
Immunity: Acc. to EN 55103-2 / EN 50130-4 / EN 50121-4
Emissions: Acc. to EN 55103-1 / FCC-47 part 15B
Emergency: Acc. to EN 60849 / EN 54-16 / ISO 7240-16
Maritime: Acc. to IEC 60945

Mechanical

Mounting
Bracket (2 screws)
Dimensions (HxWxD)
Without bracket: 27 x 243 x 80mm (1.06 x 9.57 x 3.15")
With bracket: 34 x 243 x 84mm (1.34 x 9.57 x 3.31")
Weight
0.7kg (1.54 lbs)