Audix AP42C210A, R42 Two Channel Diversity Receiver, H60/OM2 Handheld Transmitter and B60 Bodypack Transmitter

Vendor: Audix
Descriptions Audix AP42C210A, WIRELESS,R42,COMBO, W/ OM2 & ADX10, R42 Two Channel Diversity Receiver, H60/OM2 Handheld Transmitter and B60 Bodypack Transmitter with ADX10 Lavalier Microphone The Audix AP42C210A features its performance series dual-channel combo wireless system...
$1,249.00 $1,499.00
Title

Audix AP42C210A, WIRELESS,R42,COMBO, W/ OM2 & ADX10, R42 Two Channel Diversity Receiver, H60/OM2 Handheld Transmitter and B60 Bodypack Transmitter with ADX10 Lavalier Microphone

The Audix AP42C210A features its performance series dual-channel combo wireless system from Audix. The Audix AP42C210A has includes the R42 2-channel diversity receiver, B60 bodypack transmitter with ADX10 miniaturized lavalier condenser microphone, and H60/OM2 handheld transmitter. The system of the Audix AP42C210A combines the hands-free convenience of a lavalier with the flexibility of a handheld microphone. The Audix AP42C210A is suitable for presentations, meetings or events where the lead speaker remains in control while the handheld microphone is passed around either on stage or in the audience.

The R42 receiver operates on a frequency range of 522 to 554 MHz and can offers one-touch auto scan searches for clear channel. The receiver R42 in Audix AP42C210A can be easily linked to the B60 bodypack and the H60 handheld transmitters via infrared beam using its one-touch sync function, and placed within 300'. Both the transmitter units of the Audix AP42C210A comes with a soft mute switch which also serves as an on and off switch when needed and feature a high-contrast LCD display with group, channel, and battery indicator.

Audix AP42C210A Product Features

R42 Two Channel Diversity Receiver
- 32 MHz Wide spectrum tuning receiver
- 106 pre-coordinated frequencies
- One-touch auto scan searches for clear channel
- One-touch sync links transmitter to receiver via infrared beam

H60 OM2 Handheld Transmitter
- 64 MHz Wide spectrum transmitter with OM2 dynamic capsule module
- Durable metal housing
- 14 Hour run time - AA batteries

B60 L10 Bodypack Transmitter
- 64 MHz Wide spectrum transmitter with ADX10 lavalier microphone
- Durable metal housing
- 14 Hour run time - AA batteries 

Audix R42 Kit-A Performance Series Dual-Channel UHF Diversity Receiver (A: 522 To 554 MHz)<span> </span>Specs

Frequency Band  522 to 554 MHz
Bandwidth  32 MHz
# Of Simultaneous Systems  Up to 8
Switchable Frequencies  106 pre-coordinated frequencies
Wireless Range  Up to 300' / 91 m
Antenna Connector  2 x BNC (8 VDC, 150 mA)
Outputs  2 x XLR 3-pin balanced
 2 x 1/4" TS unbalanced
Audio Output Level  XLR: -12 dBV at 25 kHz deviation, 600-Ohm   load, +6 gain
 1/4": -18 dBV at 25 kHz deviation, 10-Ohm load,   +6 gain
Audio Level Control  -12 to +9 dB in 3 dB steps
Frequency Response  45 Hz to 18 kHz
Compander  2:1
Pilot Tone  32 kHz
Receiving System  Single tuner, antenna diversity
Signal to Noise Ratio  105 dB at 30 kHz deviation (A-weighted)
Total Harmonic Distortion (THD)  ≤0.7% (33 kHz deviation at 1 kHz)
Sensitivity  5 dBµV (S/N 60 dB at 25 kHz deviation, A-   weighted)
Power Requirement  100 to 240 VAC, 50/60 Hz, 12 VDC, 1 A
Dimensions (W x D x H)  16.0 x 8.2 x 1.7" / 406 x 209 x 44 mm
Weight  4.8 lb / 2.2 kg

 

Audix B60 Performance Series Bodypack Transmitter (522 To 586 MHz)<span> </span>Specs

RF Power Output  10/30 mW
Bandwidth  64 MHz
Gain Adjustment  0 dB, -6 dB, -12 dB, -24 dB
Inputs  1 x mini-XLR 3-pin
Input Impedance  Mic: 10 kOhms
 Line: 1 MOhm
Maximum SPL  Approximately 128 to 140 dB (depending on   microphone)
Battery Life  Approximately 14 hours
Current Consumption  110 mA typical
Power Requirement  2 x AA 1.5 V batteries
Dimensions (W x L x D)  2.6 x 3.5 x 0.7" / 67 x 90 x 17 mm
Weight  3 oz / 85 g without batteries
Audix ADX10 Miniature Cardioid Condenser Lavalier Microphone<span> </span>Specs
Transducer  Condenser
Polar Pattern  Cardioid
Frequency Response  50Hz to 18KHz
Dynamic Range (Typical)  not specified by manufacturer
Signal-to-Noise Ratio  not specified by manufacturer
Maximum Input Sound Level  130dB
Power Requirements  Audix Beltpack Transmitters or APS-910 Phantom   Power Supply (not included)
Output Impedance  1000 ohms
Output Connectors  Mini-XLR
Pad  No
Low Frequency Roll-Off  No
Dimensions  not specified by manufacturer
Weight  not specified by manufacturer
Audix H60 OM2 64 MHz Handheld Microphone Transmitter With OM2 Hypercardioid Dynamic Capsule (522 To 586 MHz)<span> </span>Specs
Type  Dynamic
Polar Pattern  Hypercardioid
Capsule  VLM Type B
Frequency Response  50 Hz to 16 kHz
Maximum SPL  ≥140 dB
Impedance  290 Ohms
Sensitivity  1.6 mV/Pa at 1 kHz
Off-Axis Performance  Rejection >25 dB
RF Power Output  10/30 mW
Bandwidth  64 MHz
Gain Adjustment  0 dB, -6 dB, -12 dB
Battery Life  Approximately 14 hours
Current Consumption  110 mA typical
Power Requirement  2 x AA 1.5 V batteries
Dimensions (Diam. x L)  2.1 x 10.4" / 53 x 265 mm
Weight  11 oz / 312 g without batteries