LAB GRUPPEN D 200:4L_US4 20,000W Amplifier with 4 Flexible Output-Channels, Lake Digital Signal Processing and Digital Audio Networking for Installation Applications (D 200:4L_US4)
Vendor: Lab Gruppen
Available
LAB GRUPPEN D 200:4L_US4 20,000W Amplifier with 4 Flexible Output-Channels, Lake Digital Signal Processing, and Digital Audio Networking for Installation Applications (D 200:4L_US4)
The D 200:4L merges 20,000 W of adaptable power with cutting-edge Lake DSP, DANTE Digital Audio Networking, and advanced System Integrity Monitoring. Drawing from the robust and high-powered foundation of our esteemed PLM Series, the D 200:4L embodies reliability and sonic excellence, proven in the most challenging concert tours and significant installations globally. This amplifier channels these core technologies to cater to the most rigorous digitally networked sound applications. It’s primed for use in expansive venues like stadiums, arenas, theme parks, performing arts centers, racecourses, and large-scale commercial installations. Moreover, the D Series integrates enhanced output stage technologies and installation-focused hardware and software features. These innovations optimize amplifier system design and configuration, enabling integrators to reduce initial equipment costs and drive down long-term energy consumption for end users.
Rational Power Management (RPM)
At the heart of the D Series lies Rational Power Management (RPM), a Lab Gruppen proprietary technology empowering system designers and integrators with unprecedented control over output power allocation for optimized performance in varying load conditions. This innovation allows for smarter use of resources, reducing the need to oversize amplifiers to meet maximum power demands on individual channels, which often results in wasted capacity. With RPM, the D 200:4L enables reallocating power across its four channels, with each channel capable of delivering up to 5000 W, effectively utilizing available power for different load requirements.
CAFE for Green Credentials
The D 200:4L offers seamless configuration and monitoring through the CAFE (Configuring Amplifiers For the Environment) software suite. CAFE not only facilitates in-depth system surveillance and RPM feature configuration but also introduces the Equipment Specification Predictor (ESP). ESP analyzes system and load requirements, providing precise installation recommendations for D Series units, including model and quantity needed, heat generation, channel distribution, and current draw. This comprehensive approach ensures accurate mains management and specific cooling systems or UPS specifications if necessary.
The Power of Lake Processing
The D Series Lake amplifiers offer unparalleled input flexibility, leveraging exclusive Lake processing algorithms for exceptional power and control. With seamless integration into Dante digital audio networks and compatibility with third-party middleware, these amplifiers can easily integrate into widely used digital matrix systems. Featuring four full-featured Lake Processing modules across all models, they support four discrete channels of audio throughput, allowing selection from analog and digital inputs. Each channel offers selectable input signals, failover programming, and a full-featured onboard Lake processor with advanced EQ filters and industry-leading peak and RMS limiters for superior loudspeaker protection and sound clarity.
Rational Power Management
The Rational Power Management (RPM) technology within the D 200:4 amplifier enables an optimal and flexible allocation of its 20,000 W power across its four channels. Each channel can deliver up to 5000 W individually without requiring bridging, preserving the channel count. This allocation method ensures efficient use of the amplifier inventory, allowing the remaining power to be distributed among other channels based on specific demands. This capability ensures the D 200:4 meets the needs of most performance installations without compromise, even in power-demanding applications.
Lake Processing with DANTE
The robust power platform of D Series works hand-in-glove with dual integrated Lake Processing modules. Lake features such as Raised Cosine Equalization™, Limiter Max™ peak and RMS limiters, and Iso-Float™ ground isolation. AES3 digital and dual-redundant Dante networked inputs are standard for compliance in mission-critical PA/VA applications.
Real World Green Credentials
The synergistic blend of innovative power supply technologies, delivering unparalleled low current draw for power output, along with the advanced CAFE software, revolutionizes mains management. This dynamic combination not only enhances overall efficiency but also facilitates significant cost savings on crucial infrastructure elements like cooling and UPS systems. This ultimately reduces both initial installation costs and ongoing operational expenses for venue audio systems.
PRODUCT FEATURES
-
20,000 Watt amplifier with 4 flexible output channels and up to 5,900 Watts channel output
-
Lake digital signal processing for unparalleled loudspeaker management and system control
-
Integrated 8x8 channels of dual redundant Dante digital audio networking with AES67 support
-
4 x 4,400 Watts into 2 Ohms, 4 x 5,000 Watts into 2.67 Ohms, 4 x 4,400 Watts into 4 Ohms, 4 x 2,300 Watts into 8 Ohms, 4 x 1,150 Watts into 16 Ohms, 4 x 3,300 Watts into Hi-Z 70 V, 4 x 4,700 Watts into Hi-Z 100 V
-
Proven and reliable Class-TD output stage with proprietary Intercooler high-efficiency cooling system
-
Rational Power Management (RPM) provides total flexibility to allocate available power across all 4 output channels
-
Best-in-class Power Factor Correction (PFC) with Current Draw Modelling reduces running costs and minimizes environmental impact
-
Under-voltage limiting (UVL) for continued operation during severe mains supply voltage drops
-
Dedicated on-board surveillance and load monitoring for mass notification applications
-
Redundant audio inputs and on-board system surveillance for voice alarm systems
-
CAFE (Configuring Amplifiers For the Environment) software for design, system planning, equipment planning, installation and commissioning
-
Control and monitoring integration with 3rd-party matrix systems including MediaMatrix and Q-Sys via dedicated interfacing software
-
Dedicated front-panel mute buttons for each amplifier channel with bicolor LED indication
-
4 "Lake Class" analog input channels with Iso-Float ground isolation for reliable audio distribution
-
4 input channels of AES/EBU (AES3) digital audio supporting all standard sample rates up to 192 kHz with 24-bit resolution
-
2 Neutrik etherCON RJ-45 ports provide dual redundant Dante interfaces and remote configuration via Lake Controller and Dante Controller software
-
Balanced analog and digital audio inputs and amplifier outputs on plug-in Phoenix connectors
-
Detachable Neutrik powerCON cable rated at 250 V / 32 A with a variety of wall plugs selectable on order
-
Removable dust filter grille for increased air circulation and simple maintenance
-
Rugged 2U rackmount chassis including rear support brackets for ease of installation
General
Processing / Network |
Lake / Dante |
Number of amplifier channels |
4 |
Total burst power all channels (share among channels with RPM) |
20000 W |
Max output power (all channels driven)1
2 ohms |
4400 W |
2.67 ohms |
5000 W |
4 ohms |
4400 W |
8 ohms |
2300 W |
16 ohms |
1150 W |
Hi-Z 70 V |
3300 W |
Hi-Z 100 V |
4700 W |
Max output power single channel (all models)1
2 ohms |
4400 W |
2.67 ohms |
5900 W |
4 ohms |
4600 W |
8 ohms |
2300 W |
16 ohms |
1150 W |
Hi-Z 70 V |
3300 W |
Hi-Z 100 V |
4700 W |
Amplifier output modules (all models, all channels)
Peak output voltage |
194 V |
Max. output current |
67 A |
Rational Power Management (RPM) |
Regardless of model, any channel has potential to deliver the max single channel output power (1 channel on D 80:4, 2 channels on D 120:4) |
Default voltage limitation (can be lifted with RPM configuration) |
194 V |
Protection features |
Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Short Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection |
Amplifier platform
Inter Sample Voltage Peak Limiter (ISVPL) |
Configurable Peak voltage threshold and profile |
THD + N at 1 kHz and 1 dB below clipping |
< 0.04 % |
Pilot tone generation and analysis |
Yes |
Load impedance analysis |
Yes |
Frequency response (1 W into 8 Ohm, 20 Hz - 20 kHz) |
+/- 0.05 dB |
Internal Sample Rate / Data path |
48 / 96 kHz / 32 bit floating point |
Product propagation delay AES 96 kHz / analog input |
1.61 / 1.68 ms |
Lake processing
Loudspeaker processing |
Up to 4 modules of Classic/linear-phase/FIR crossover, EQ, delay, LimiterMax™ - peak and RMS limiters |
System tuning |
Group control with Raised Cosine™ MESA EG™ asymmetric filters |
Input redundancy / Matrix |
Automatic 4 level input redundancy / 4 input mixers |
System integration |
Comprehensive 3rd party protocol over UDP Ethernet |
Dante Audio Network
Dante I/O |
8 x 8 |
Network topology / redundancy |
Flexible topology / Supports daisy-chained and Dual redundant networks |
Sample Rates / Transport |
48, 96 kHz / Uni + Multicast |
Network latency |
0.25, 0.5, 1.0, 2.0, 5.0 ms |
AES Inputs
Inputs |
2 AES inputs (4 audio channels) |
Supported sample rates / resolution |
44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits |
Sample rate conversion THD+N 20 Hz - 20 kHz unweighted |
0.0000003 |
Analog Inputs
Inputs |
4 high quality inputs with Iso-Float ground isolation |
Maximum input / digital reference |
+26 dBu / +21 dBu |
Sampling rate / Resolution |
96 kHz / 24 bit |
Input impedance balanced / unbalanced |
20 / 10 kOhm |
THD+N (typical at 1 kHz unweighted) |
0.0000022 |
THD+N (typical at 20 Hz and 20 kHz unweighted) |
0.0000033 |
Back panel Interface
Analog inputs |
4 x Terminal block connectors analog input with +, - and ground |
AES inputs |
4 x Terminal block connectors analog input with +, - and ground |
Output connectors |
4 x 2 pole Terminal block connectors rated at 1000 V / 76 A (exceeding amplifier capacity) Can take up to 16 mm2 (6 AWG) cables |
Ethernet Ports |
2 x EtherCon RJ45 100/1000 Base-T for the Lake Controller, Dante controller and/or DLM (3rd party protocol) |
Detachable mains cord |
Neutrik PowerCon rated at 250V/32A |
Front-panel user interface
System status indication |
3 x 3 colored LED. FRAME, TEMP, PSU for device status indication |
Channel status indication |
3 x 3 colored LED per channel. Status indication separated for channel LOAD, AMP, SIGNAL status |
Mute |
Per channel touch button for mute control and bicolored LED for indication |
Power |
Touch button for ON/STANDBY control and bicolored LED for power state indication |
Select |
Touch button and LED for bidirectional Device -Software select functionality |
Mains Power
Nominal voltage |
100 - 240 Volt AC 50 - 60 Hz |
Operating voltage |
70 - 265 V AC 45 - 66 Hz |
Mains wall plug |
Selectable on order CEE 7/7 “Schuko” 230 V / 16 A NEMA L5-30 “Twistlock” 125 V / 30 A NEMA 5-15P 125 V / 15 A (D 80:4 only) NEMA 5-20P 125 V / 20 A (D 120:4 only) NEMA 6-20P 250 V / 20 A AS/NZS 3112 230 V / 15 A (Aus/Nz) BS 546 230 V / 16 A (India) C-30P 125 V / 30 A (Japan) |
Power supply features
Soft start / Inrush power |
Yes/ Max 8 Ampere |
Power factor correction |
> 0.98 for mains power > 400 W |
Regulated switch mode power supply (R.SMPS) |
Yes |
Breaker Emulation Limiter (BEL) |
Configurable current threshold and breaker profile |
BEL max current threshold |
32 A |
Power Average Limiter (PAL) |
Yes |
Under Voltage Limiter (UVL) |
Yes |
Mains undervoltage and overvoltage protection and mains glitch tolerance |
Yes |
Dimensions
Rack rail to rear panel |
W: 483 mm (19"), H: 88 mm (2 U), D: 424 mm (16") |
Overall depth front-rear support |
D: 463 mm |
Weight
Weight |
16.5 kg (36 lbs) |
Finish
Finish |
Black painted steel chassis with grey painted steel front with detachable grille |